  sx - series pressure sensors march 1998/052 aubinger weg 27, 82178 puchheim, germany phone 0049 - (0) 89 80 08 30, fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com features 0 ... 1 to 0 ... 300 psi absolute, differential and gage devices high impedance bridge low power consumption for battery operation applications industrial controls pneumatic controls medical instrumentation barometry equivalent circuit button sensor or "n" package to can or dip package general description the sx series of pressure sensors provide the most cost effective method of measuring pressures up to 150 psi. these sensors were specifically designed to be used with non-corrosive and non-ionic media, such as air and dry gases. convenient pressure ranges are available to measure differential, gage, and absolute pressures from 0 to 1 psi (sx01) up to 0 to 300 psi (sx7300d). the absolute (a) devices have an internal vacuum reference and an output voltage proportional to absolute pressure. the dif- ferential (d) devices allow application of pressure to either side of the diaphragm and can be used for gage or differential pressure measurements. however, 300 psi (sx7300d) can be applied to pressure port p2 only. pressure port p1 is able to handle operating pressures up to 150 psi only. this product is packaged either in sensyms standard low cost chip carrier "button" package, a plastic ported "n" package, a metal to can package or a dual inline package (dip). all packages are designed for applications where the sen- sing element is to be integral to the oem equipment. these packages can be o-ring sealed, epoxied, and/or clamped onto a pressure fitting. a closed bridge four-pin sip configuration is provided for electrical connection to the button or "n" package. the to can offers a 5-pin open bridge configuration. because of its high-impedance bridge, the sx series is ideal for portable and low power or battery operated systems. due to its low noise, the sx is an excellent choice for medical and low pressure measurements. for further technical information please contact the factory. scale: 5 m m ? inch electrical connection button sensor buttom view (open bridge) sxxxxgd2 dip sxxxxad2 sxxxxd4 dip the polarity indicated is for pressure applied to: sx... : p1 (forward gage) sx...as/gso : p1 (forward gage) sx...ad2 : p1 (forward gage) sx...gd2 : p2 (backward gage) sx...dd4 : p2 (backward gage)
sx - series pressure sensors march 1998/052 aubinger weg 27, 82178 puchheim, germany phone 0049 - (0) 89 80 08 30, fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com maximum ratings (for all devices) suppy voltage, v s +12 v dc temperature ranges operating -40c to +85c storage -55c to +125c maximum pressure at any port 11 150 psig lead temperature (soldering 4 sec) 250 c characteristic temperature coefficient of span 6, 9 zero pressure offset t a = 25c 12 temperature coefficient of offset 5, 9 combined linearity and hysteresis 3 long term stability of offset and sensitivity 8 response time (10% to 90%) 7 input resistance t a = 25c temperature coefficient of resistance 6, 9 output impedance repeatability 4 sx15..., sx30..., sx100..., SX150... min -2400 -35 --- --- --- --- --- +690 --- --- typ -2150 -20 +4 0.2 0.1 0.1 4.65 +750 4.5 0.5 max -1900 0 --- 0.5 --- --- --- +810 --- --- unit ppm/c mv v/v/c %fs %fs ms k w ppm/c k w %fs pressure sensor characteristics proof pressure 10 sx01 20 psi sx05 20 psi sx15 30 psi sx30 60 psi sx100 150 psi SX150 200 psi sx7300 forward gage, p1 250 psi sx7300, backward gage, p2 500 psi characteristic temperature coefficient of span (6,9) zero pressure offset t a = 25c (12) temperature coefficient of offset (5,9) combined linearity and hysteresis (3) long term stability of offset and sensititvity (8) response time (10% to 90%) (7) input resistance t a = 25c temperature coefficient of resistace (6,9) output impedance repeatability (4) min. -2550 -35 --- --- --- --- --- +690 --- --- typ. -2300 -20 +4 0.2 0.1 0.1 4.65 +750 4.65 0.5 max. -2050 0 --- 0.5 --- --- --- +810 --- --- unit ppm/c mv v/v/c %fs %fs ms k w ppm/c k w %fs performance characteristics (1) sx01, sx05 part number sx01... sx05... sx15... sx30... sx100... SX150... sx7300 forward gage sx7300 backward gage operating pressure 0 - 1 psid 0 - 5 psid 0 - 15 psi (a) d 0 - 30 psi (a) d 0 - 100 psi (a) d 0 - 150 psid 0 - 100 psig 0 - 300 psig proof pressure 10 0 - 1 psid 0 - 5 psid 0 - 15 psi (a) d 0 - 30 psi (a) d 0 - 100 psi (a) d 0 - 150 psid 0 - 100 psig 0 - 300 psig full scale span min. 15 mv 50 mv 75 mv 75 mv 100 mv 75 mv --- 45 mv typ. 20 mv 75 mv 110 mv 110 mv 150 mv 110 mv --- 70 mv max. 25 mv 100 mv 150 mv 150 mv 200 mv 150 mv --- 95 mv
sx - series pressure sensors march 1998/052 aubinger weg 27, 82178 puchheim, germany phone 0049 - (0) 89 80 08 30, fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com characteristic temperature coefficient of span (6, 9) zero pressure offset t a = 25c temperature coefficient of offset (5, 9) combined linearity and hysteresis (3) long term stability of offset and sensitivity (8) response time (10% to 90%) (7) input resistance t a = 25c temperature coefficient of resistance (6, 9) output impedance repeatability (4) unit ppm/c mv v/v/c %fs %fs ms k w ppm/c k w %fs max -1900 40 --- 0.5 --- --- 6.0 --- --- --- typ -2150 0 +4 0.1 0.1 0.1 4.5 +750 4.65 0.3 min -2400 -40 --- --- --- -- 3.0 --- --- --- sx7300... typical performance characteristics
sx - series pressure sensors march 1998/052 aubinger weg 27, 82178 puchheim, germany phone 0049 - (0) 89 80 08 30, fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com button sensor element the button sensor element was de- signed to allow easy interface with additional cases and housings which then allow pressure connection. the device can be mounted with an o-ring, gasket, or rtv seals on one or both sides of the device. the device can then be glued or clamped into a variety of fixtures and the leads can be bent as necessary to allow for ease of electrical connection. however, caution is advised as repeated bending of the leads will cause eventual breakage. for most gage applications, pressure should be applied to the top side of the device. (see physical construction drawing.) for differential applications, the top side of the device (p1) should be used as the high pressure port and the bottom (p2) as the low pressure port (except for sx7300d, where p2 is the high pressure port). the button sx package has a very small internal volume of 0.06 cubic centimeters for p1 and 0.001 cubic centimeters for p2. n packaged sensor the "n packaged sensor is designed for convenient pressure connection and easy pc board mounting. to mount the device horizontally to a pc board, the leads can be bent downward and the package attached to the board using either tie wraps or moun- mechanical and mounting considerations ting screws. for pressure attachment, tygon or silicon tubing is recommended. the n package version of the sensor has two (2) tubes available for pressure connection. for gage devices, pressure should be applied to port p1. for differential pressure applications, port p 1 should be used as the high pressure port and p2 should be used as the low pressure port. to package the to package parts are available with pressure access only to p1 for absolute and gauge pressure. therefore, on gauge devices the bottom of the to package must be left open so atmosphere. typically, tubing is attached directly around the top of the to can or the package can be glued or o-ring sealed into a fixture. as always care should be taken not to stress the package. for all sensor packages care should be taken not so expose the parts to caustic media. this includes washers for board cleaning, etc.. general discussion output characteristics the sx series devices give a voltage output which is directly proportional to applied pressure. the devices will give an increase in positive going output when increasing pressure is applied to pressure port p1 of the device. if the devices are operated in the backward gage mode, the output will increase with decreases in pressure. the devices are ratiometric to the supply voltage. changes in supply voltage will cause proportional changes in the offset voltage and full-scale span. user calibration sx series devices feature the button ic pressure sensor element. this will keep overall system costs down by allowing the user to select calibration and temperature compensation circuits which specifically match individual application needs. in most cases, the primary signal conditioning elements to be added so the sx by the user are: offset and span calibration and temperature compensation. some typical circuits are shown in the application section. vacuum reference (absolute devices) absolute sensors have a hermetically sealed vacuum reference chamber. the offset voltage on these units is therefore measured at vacuum, 0 psia. since all pressure is measured relative to a vacuum reference, all changes in barometric pressure or changes in altitude will cause changes in the device output. media compatibility sx devices are compatible with most non- corrosive gases. because the circuitry is coated with a protective silicon gel (parylene coating for all to can devices), some otherwise corrosive environments can be compatible with the sensors. as shown in the physical construction diagram below for the button sensor element and ,,n package, fluids must generally be compatible with silicon gel, rtv, plastic, and aluminum for forward gage use and rtv, silicon, glass and aluminum for backward gage or differential applications. for questions concerning media compatibility, contact the factory. physical construction
sx - series pressure sensors march 1998/052 aubinger weg 27, 82178 puchheim, germany phone 0049 - (0) 89 80 08 30, fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com application information general the sx family of pressure sensors functions as a wheatstone bridge. when pressure is applied to the device (see figure i) the resistors in the arms of the bridge change by an amount d . figure i. button sensor bridge schematic the resulting differential output voltage v 0 , is easily shown to be v o = v b x d . since the change in resistance is directly proportional to pressure, v o can be written as: v o = s x p x v b v os (1) where: v o is the output voltage in mv s is the sensitivity in mv/v per psi p is the pressure in psi v b is the bridge voltage in volts. v os is the offset error (the differential output voltage when the applied pressure is zero). the offset voltage presents little problem in most applications, since it can easily be corrected for in the amplifier circuitry, or corrected digitally if a microprocessor is used in the system. temperature effects in this discussion, for simplicity of notation, the change of a variable with temperature will be designated with a dot (?) over the variable. for example, ? change in sensitivity d s change in temperature d t from equation (1), and ignoring the v os term, it in seen that for a given constant pressure, the output voltage change, as a function of temperature*, is: ?? v o = spv b (2) thus, in order for output voltage to be independent of temperature, the voltage across the bridge, v b , must change with temperature in the "opposite direction from the sensitivity change with temperature. from the typical curves for the temperature dependence of span (span = s x p x v b ), s == it can be seen that the sensitivity change with temperature is slightly non-linear and can be correlated very well with an equation of he form: s = s o [(1 - ?t d ) + r t d 2 ] (3) where t d is the temperature difference between 25c and the temperature of inte- rest, s o is the sensitivity at 25c, and beta (?) and rho ( r ) are correlation constants. fortunately, between 0c and 70c the change in sensitivity with tem-perature is quite linear, and excellent results can be obtained over this temperature range by ignoring the second-order temperature dependent term. operating outside the 0c and 70c temperature range will require a more rigorous mathematical approach and the use of non-linear compensating cir- cuitry, if accuracy of better than 1% is re- quired. because the majority of sx appli- cations fall within the 0c to 70c operating temperature range, the discussion and circuit designs given here will ignore the non-linear effects. thus: s = s o (1 - ?t d ) (4) substituting equation (4) into equation (1) and ignoring v os , it can be shown that the necessary bridge voltage, v b , will be of the form: v bo (1-?t d) where v bo is the bridge voltage at 25c. this equation is again non-linear. however, for the temperature range of interest, and since ? is small (0.215%/c from the electrical tables), the above expression can be approximated by: v b =v bo [1 +?t d ] with less than 1% error. thus to com- pensate for a negative 2150 ppm/c sensitivity change with temperature, the bridge voltage should increase with temperature at a rate of +2150 ppm/c. the above value of bridge voltage change will be used in the circuit discussions that follow. that is to say, the required change in terms of ppm/c is: ? = +2050 ppm/c the bridge input resistance*, r b also changes with temperature and is quite linear in the temperature range of interest. the bridge resistance has a temperature coefficient of typically: ? = +750 ppm/c this term enters into several compensation v b= =v bo [(1 - ?t d + (?t d ) 2 +...)] circuit equations, particularly when the bridge excitation is from a constant current source. to summarize, the following list indicates how the sensor variables can be accommo- dated ? full-scale span from device to device. make the gain adjustment in the op amp circuitry ? temperature coefficient of span: 1) temperature compensate the bridge or 2) temperature compensate the op amp gain ? offset voltage: adjustment in op amp circuitry ? offset voltage temperature coefficient: usually can be ignored. for more precise design requirements, contact the factory for information on how to compensate for this term. bridge compensation circuits although thermistors can be used to temperature compensate the bridge (and in fact will be required for extended tempe- rature operation), they are inherently non- linear, difficult to use in volume production, and more expensive than the circuit appro- aches shown here, which use inexpensive semiconductor devices the circuits shown have been designed to incorporate a mini- mum number of adjustments and allow interchangeability of devices with little variation from device to device. in general, equations for the bridge voltage and its change with temperature are given to enable the user to modify or adjust the circuitry as required. 1. diode string (figure ii) for systems using 6v supplies, this method of compensating for the effects of span over temperature is the lowest cost solution the diodes are small signal silicon diodes, such as 1n914 or 1n4148, and do not have to be matched. figure ii. diode string span compensation v b v b ( ) r b r b ( )
sx - series pressure sensors march 1998/052 aubinger weg 27, 82178 puchheim, germany phone 0049 - (0) 89 80 08 30, fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com v b r b i o v s v b r b i o v b ( ) ( ) ( )[ ( )] 67.7 mv r 1 a) v b = a (v s + i o r 2 ) ? ? b) = (1 - a )+ 1- a c) a = ? ? d) = 3360 ppm/c, =+750ppm/c e) i o= the design steps are straight forward: 1) knowing v s and the desired bridge voltage v b , solve equation (b) for a . 2) now, solve equation (c) for r 2 , letting r b = 4650 w . 3) solve equation (a) for i o . 4) find r 1 or its nearest 1% tolerance value from equation (e). table ii gives specific 1% resistor values in ohms, for several popular system voltages. for best results, the resistors should be 1% metal film with a low temperature coefficient. table ii. selected r values vs v s for figure iv v s v b r 1 ( w w w w w )r 2 ( w w w w w ) 5v 3v 147 11.0k 6v 4v 105 9.53k 9v 6v 68.1 9.53k 12v 9v 43.2 8.25k 15v 10v 41.2 9.53k amplifier design there are hundreds of instrumentation amplifier designs, and the intent here will be to briefly describe one circuit which: does not load the bridge involves minimal components provides excellent performance amplifier adjustment procedure 1. without pressure applied, (a) short points a and b together as shown in figure v. adjust the 1k common-mode rejection (cmrr) pot until the voltage at test point (t p ) v x is equal to the voltage at test point (t p ) v r . this is easily accomplished by placing a digital voltmeter between these test points and adjusting for 0.000. r b r 2 + r b i o r b i o r b ( ) ( ) a) v b =v s -4 f b) v b v b v s f c ) = -2500 ppm/c for silicon diodes figure ii. equations for example, solving equation (b) for v b / v b when v s = 6.0 v f = 0.7 v yields: = 2188 ppm/c since the sensors span changes with temperature at -2150 ppm/c, this technique will typically result in an overall negative tc of 38 ppm/c. this error is acceptable in most applications. for operation with v s above 6v, it is recommended to use the transistor or constant current compensation technique. 2. transistor compensation network figure iii uses a single transistor to simulate a diode string, with the equations as shown. the values shown in table i were found to give excellent results over 0c to 70c. again, if precision temperature compensation is required for each device, the fixed value resistors shown for r1 in table i can be replaced by a 3.24k resistor in series with a 1k pot. then, each devices temperature compensation can be individually adjusted. figure iii. transistor/resistor span tc compensation -4 ( ) ( ) ( ) f f ( ) f f = v b v b ? a) v b = v s - a f b) = - x - a c) a =1+ d) f f table i. selected r values vs v s for figure iii v s r 1 ( w w w w w )r 2 ( w w w w w ) 5v 3.32k 1.43k 9v 4.02k 806 12v 4.22k 604 3. constant current excitation (figure iv) the circuits shown in figures ii and iii, although simple and inexpensive, have one drawback in that the voltage across the bridge is determined by the compensations network. that is, the compensation network is determined and what voltage is leftover" is across the bridge. the circuit of figure iv solves this problem and allows the bridge voltage to be independently selected. in figure iv, the bridge is driven from a constant current source, the lm334, which has a very well known and repeatable temperature coefficient of +3300 ppm/ c. this temperature coefficient (tc), in conjunction with the tc of the bridge resis- tance, is too high to compensate the sensitivity tc, hence resistor r 2 is added to reduce the total circuit tc. the basic design steps for this method of temperature compensation are shown below. however, please refer to sensyms application note ssan-16 for details on the temperature compensation technique. figure iv. constant current span tc compensation ( ) ( ) ( ) v b fa v b f v s f r 1 r 2 = -2500 ppm/c ( ) ? application information (cont.) ? ? ??
sx - series pressure sensors march 1998/052 aubinger weg 27, 82178 puchheim, germany phone 0049 - (0) 89 80 08 30, fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com table iii. for 0 to 70c operation span v s v b r 2 r 1 fs r 5 r p 5v 3.5v 9.09k 118 w 3v 604 w 2k 6v 4.5v 8.45k 86.6 w 4v 604 w 2k 9v 7v 7.87k 54.9 w 5v 1k 2k 12v 10v 7.15k 36.5 w 5v 1.82k 5k 12v 10v 7.15k 36.5 w 10v 511 w 2k 15v 12v 7.68k 31.6 w 5v 1.4k 5k 15v 12v 8.87k 31.6 w 10v 604 w 2k application information (cont.) (b) remove the short and adjust the 500 w offset adjust pot until v x is again equal to v r . (c) adjust the 2k reference (v r ) adjust pot to get an output voltage (v o ) equal to 1.00v. 2. apply the fuii-scale pressure and adjust the span adjust pot, r 5 , to get the output voltage that is desired to represent full- scale. note: application information shown here is based on the closed bridge configuration. the choice of the operational amplifiers to use is based on individual cost/perfor- mance trade-offs. the accuracy will be primarily limited by the amplifiers common- mode rejection, offset voltage drift with temperature and noise performance. low cost, low performance devices, such as the lm324 can be used if the temperature ranges limited to 25c +15c and an accuracy of +2% is adequate. for more precise applica-tions, amplifiers such as the lt1014 and lt1002 have been found to be excellent. an amplifier that uses a single supply is shown in figure v. table iii gives resistor values for various supply and full-scale output combinations. factory compensated devices this application note provides the necessary information for temperature compensating and calibrating the sx sensors. in some case, the customer may find that sx devices which have been factory adjusted for temperature compensation and span are more economical for a particular application. sensym does offer devices with this feature. for more information on these factory calibrated and compensated devices, the scx series and sdx series, please contact sensortechnics. figure v: button sensor amplifier circuit 10k r g a lt1014cn b lm10cn v o = 4 1 + v in + v r resistors labled r 3 , r4 are 5-element resistor arrays 10 k w . two required [ ]
sx - series pressure sensors march 1998/052 aubinger weg 27, 82178 puchheim, germany phone 0049 - (0) 89 80 08 30, fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com physical dimensions button package n package aho package (to-5) gso package (to-39)
sx - series pressure sensors march 1998/052 aubinger weg 27, 82178 puchheim, germany phone 0049 - (0) 89 80 08 30, fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com physical dimensions basic sensor dip "d2" package basic sensor dip "d4" package
sx - series pressure sensors march 1998/052 aubinger weg 27, 82178 puchheim, germany phone 0049 - (0) 89 80 08 30, fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com pressure range absolute pressure 0 - 15 psi 0 - 30 psi 0 -100 psi 0 -150 psi gage pressure 0 - 1 psi 0 - 5 psi 0 -15 psi 0 -30 psi 0 -100 psi 0 -150 psi 0 - 300 psi differential pressure 0 - 1 psi 0 - 5 psi 0 -15 psi 0 -30 psi 0 -100 psi 0 -150 psi order part number button package sx15a sx30a sx100a SX150a use sx01d use sx05d use differential devices sx7300d sx01d sx05d sx15d sx30d sx100d SX150d "n" package sx15an sx30an sx100an --- use sx01dn use sx05dn use differential devices --- sx01dn sx05dn sx15dn sx30dn sx100dn SX150dn to metal can package sx15aho sx30aho sx100aho --- sx01gso sx05gso sx15gso sx30gso sx100gso SX150gso --- --- --- --- --- --- --- dip"d2" package (single ported) sx15ad2 sx30ad2 sx100ad2 --- sx01gd2 sx05gd2 sx15gd2 sx30gd2 sx100gd2 --- --- --- --- --- --- --- --- dip"d4" package (dual ported) --- --- --- --- --- --- --- --- --- --- --- sx01dd4 sx05dd4 sx15dd4 sx30dd4 sx100dd4 --- ordering information to order, use the following part numbers: sensym and sensortechnics reserve the right to make changes to any products herein. sensym and sensortechnics do not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. specification notes: (for all devices) 1. reference conditions: supply voltage, v s = 5 v dc , t a = 0c to 70c, common-mode line pressure = 0 psig, pressure applied to p 1 , unless otherwise noted. 2. span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure. 3. see definition of t erms. hysteresis - the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. 4. maximum difference in output at any pressure with the operating pressure range and temperature within 0c to +70c after: a) 100 temperature cycles, 0c to +70c b) 1.0 million pressure cycles, 0 psi to full scale span 5. slope of the best straigth line from 0c to +70c. 6. this is the best straight line fit for operation between 0c and 70c. for operation outside this temperature, contact factory for more specific applications information. 7. response time for a 0 psi to full-scale span pressure step change. 8. long term stability over a one year period . 9. this parameter is not 100% tested. it is guaranteed by process design and tested on a sample basis only. 10. if the maximum pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing die may fracture. note: the proof pressure for the forward gage of all devices in the d4-package and the sx7300 is the specified value or 100 psi, whatever is less. 11. maximum pressure at any port is the maximum operating plus common-mode pressure which can be applied. 12. the zero pressure offset is 0 mv min, 20 mv typ and 35 mv max for part nos. sxxxxgd2 and sxxxxdd4.